Land & Sprache: German / German
Distributor login

Flow meter accuracy

Kytola flow meter accuracy is stated as % of F.S. (Full Scale) or % of RD (Reading). Here you can find the information about flow meter’s accuracy and calculation formula for calculating inaccuracy.

% F.S. accuracy

For example when flow meter full scale is 100 L/min and accuracy is stated as +/- 5 % F.S. it means +/- 5 L/min accuracy on the flow meter whole measurement range.

% of F.S. inaccuracy is calculated

Flow meter reading – Real flow            *100 = F.S. inaccuracy
         Flow meter full scale

% RD accuracy

For example when flow meter reading is 100 L/min and accuracy is stated as +/- 5 % RD it means +/- 5 L/min accuracy. Or at 50 L/min reading +/- 2,5 L/min accuracy.

% of RD. inaccuracy is calculated

Flow meter reading – Real flow           *100 = RD inaccuracy
         Flow meter reading

Kontaktdaten

Dieses Feld wird bei der Anzeige des Formulars ausgeblendet
Dieses Feld wird bei der Anzeige des Formulars ausgeblendet
Dieses Feld dient zur Validierung und sollte nicht verändert werden.

Woher kommen Sie?

Bitte wählen Sie Ihr Land aus, um in Ihrer eigenen Sprache und Ihren lokalen Einheiten zu suchen.