Land & språk: Sweden / Swedish
Åter­för­säl­ja­re logga in

Flow meter accuracy

Kytola flow meter accuracy is stated as % of F.S. (Full Scale) or % of RD (Reading). Here you can find the information about flow meter’s accuracy and calculation formula for calculating inaccuracy.

% F.S. accuracy

For example when flow meter full scale is 100 L/min and accuracy is stated as +/- 5 % F.S. it means +/- 5 L/min accuracy on the flow meter whole measurement range.

% of F.S. inaccuracy is calculated

Flow meter reading – Real flow            *100 = F.S. inaccuracy
         Flow meter full scale

% RD accuracy

For example when flow meter reading is 100 L/min and accuracy is stated as +/- 5 % RD it means +/- 5 L/min accuracy. Or at 50 L/min reading +/- 2,5 L/min accuracy.

% of RD. inaccuracy is calculated

Flow meter reading – Real flow           *100 = RD inaccuracy
         Flow meter reading

Kontaktinformation

Kontakta oss

Säljkontor, Sverige

Kytölä Instrument AB
Ringborregatan 1
721 34 Västerås

Hidden
Hidden
Detta fält används för valideringsändamål och ska lämnas oförändrat.

Sälj

Flow meter accuracy

Where are you from?

Please select your country to browse in your own language and local units.